MC-Basic:axis.POSITIONEXTERNALFACTOR
Language: | English • 中文(简体) |
---|
The position factor of the external feedback is used to convert that value from counts into physical units.
Short form
<axis>.PExtfac
Syntax
<axis>.PositionExternalFactor = <expression>
?<axis>.PositionExternalFactor
Availability
All versions
Type
Double
Range
Greater than 0
Default
1
Scope
Configuration, Task or Terminal
Limitations
- Drive must be disabled.
- To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
A1.PositionExternalFactor = 2048