AXY:Element Synchronization/Design

From SoftMC-Wiki
Revision as of 09:23, 31 January 2012 by Miborich (talk | contribs) (Pre-Calculation)
Jump to: navigation, search

Element Synchronization Design

Common algorithms to both SyncStart and SyncAll:


Pre-Calculation

Is done in MotionManager task, initiated by message sent from SyncStart/All commands:

In case of SyncStart we sperately execute MotCalc on every element from the sync-list: (el1 , el2 , el3 , ... eln ):

FOR element FROM sync-list
   element->MotCalc()
NEXT

In case of SyncAll it is little bit more complicated, every element is pre-calculated in order to estimate it's own max profile values:

FOR element FROM sync-list
element->MotCalc() ==> Li , Vi , Ai , Di , Jai ,  Jdi
NEXT

And then generate a master profile with the following parameters:


The master profile data-structure will be copied to the profile-data-structure of all other elements.


Master profile:

, , , , ,


where

The master profile data-structure will be copied to the profile-data-structure of all other elements.


The complete system of the sync-list motion profiles will be executed together just be scaling each of them by the factor of:



Sync List profiles