MC-Basic:element.MOTIONSTATUS
This read-only property queries the motion status of an element. The element status is returned every SERCOS communication cycle and comprises 32 bits: Bit [0] prf_stop Bit [1] prf_start Bit [2-3] prf_oper Bit [4-5] prf_mode Bit [6-7] prf_type Bit [8-11] acc_phase Bit [12-14] mot_type Bit [15] doub_mod Bit [16] sinprg Bit [17] group_axes Bit [18-20] allow_proceed Bit [21-22] unusedH Bit [23] imm_exp Bit [24] imm_chng Bit [25] stopped Bit [26] interrupted Bit [27] pending Bit [28-30] broken_counter Bit [31] sing
This flag indicates the state of the acceleration. Accstatus = (Ax.motionstatus shr 8) band 0b1111
0 = element acceleration is increasing
1 = In position 2 = acceleration decrease 3 = zero acceleration 4 = Trapez Linear acceleration is increasing 5 = Trapez acceleration satruration 6 = Trapez acceleration decreasing 7 = Trapez zero acceleration
Syntax
none
Availability
All versions
Type
Long
Range
TBD
Scope
Configuration, Task or Terminal
Limitations
Read-Only
Examples
?(Ax.motionstatus shr 8) band 0b1111