MC-Basic:element.MOTIONSTATUS

From SoftMC-Wiki
Revision as of 05:59, 17 July 2011 by EranKo (talk | contribs)
Jump to: navigation, search

This read-only property queries the motion status of an element. The element status is returned every SERCOS communication cycle and comprises 32 bits: short int prf_stop:1; // 0 short int prf_start:1; // 1 short int prf_oper:2; // 2..3 short int prf_mode:2; // 4..5 short int prf_type:2; // 6..7 short int acc_phase:4; // 8..11 short int mot_type:3; // 12..14 short int doub_mod:1; // 15 short int sinprg:1; // 16 short int group_axes:1; // 17 short int allow_proceed:3; // 18-19-20 short int unusedH:2; // 21..22 short int imm_exp:1; // 23 short int imm_chng:1; // 24 short int stopped:1; // 25 short int interrupted:1; // 26 short int pending:1; // 27 short int broken_counter:3; // 28..30 short int sign:1; // 31







This flag indicates the state of the acceleration. Accstatus = (Ax.motionstatus shr 8) band 0b1111

       0 = element acceleration is increasing

      1 = In position
      2 = acceleration decrease
      3 = zero acceleration
      4 = Trapez Linear acceleration is increasing
      5 = Trapez acceleration satruration
      6 = Trapez acceleration decreasing
      7 = Trapez zero acceleration

Syntax

none

Availability

All versions

Type

Long

Range

TBD

Scope

Configuration, Task or Terminal

Limitations

Read-Only

Examples

?(Ax.motionstatus shr 8) band 0b1111

See Also