MC-Basic:pls.PLSREPEAT

From SoftMC-Wiki
Revision as of 16:00, 13 December 2010 by Arwiebe (talk | contribs) (Created page with '{{MC-Basic |SHORT FORM= ''<pls>''.Prep |SYNTAX= ''<pls>''.PlsRepeat = ''<repetition interval>'' |AVAILABILITY= All versions |DESCRIPTION= Sets or queries the repetition interv…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Sets or queries the repetition interval of the PLS. The PLS output pattern specified by the PLS positions is repeated at an interval specified by the REPEAT property. A value of 0 disables repetition.

Short form

<pls>.Prep

Syntax

<pls>.PlsRepeat = <repetition interval>

Availability

All versions

Type

Double

Range

Greater than abs(maximum PLS position - minimum PLS position)

Default

0

Scope

Configuration, Task or Terminal

Limitations

The <repetition interval> is set only when the PLS is disabled.

Examples

Pls1.PlsRepeat = 1000

See Also