MC-Basic:axis.SIMULATED

From SoftMC-Wiki
Revision as of 16:00, 13 December 2010 by Arwiebe (talk | contribs) (Created page with '{{MC-Basic |SHORT FORM= |SYNTAX= ''<axis>''.Simulated = ''<expression>''<br> ?''<axis>''.Simulated |AVAILABILITY= All versions |DESCRIPTION= This property is used to define…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

This property is used to define the axis mode of operation as simulated or real. In simulated mode, motion commands are not sent to the drives as the axis is not associated with a physical drive. Simulated axes need to be enabled (using <axis>.ENABLE=ON) before a motion command is applied.
       0 (Real)
       1 (Simulated)

Syntax

<axis>.Simulated = <expression>

?<axis>.Simulated

Availability

All versions

Type

Long

Range

0 or 1

Default

0

Scope

Configuration, Task or Terminal

Limitations

Can only be set during SERCOS communications phase 0.

Examples

Xaxis.Simulated=1