AXY:Operational Modes

From SoftMC-Wiki
Revision as of 11:48, 2 February 2011 by Anonymous (talk) (Entering the analog velocity mode)
Jump to: navigation, search


1. Introduction2

2. Operation modes5

3. Setting a mode (transition between the modes)6

4. Properties and Commands22

5. Side effects28

6. Motion properties31

'7. Appendix (future features)34'Revision History:


Revision Number Description
2 * OpMode changed to WoMode (working modes), the OpMode is confusing and can be misunderstood with the drive OpMode (IDN32) (Avishai)
  • Nodal-only mode property is transposed to future-feature.
  • Torque mode uses TimeToTorque property
  • Torque command changed to DigitalTorque (Michael)
  • The STOP command does not change the operation modes.
  • WoMode (OpMode) designed as a command.
  • Position Limits are always checked.
  • Velocity-Overspeed is always checked.
  • Drive mode-change timeout (See: 5.8 Transition Timeout)


3 * Blending between modes will be disabled (5.10)
  • Waiting is done in the Motion Manager task (See 3.1.13.1.2)
  • Analog modes attach the axis (See 5.5 )
  • ProceedType=CLEAR sets the system to digital position mode (See: 5.9.2 )


Contents

Introduction

Purpose of the document

This document will give description of the SC operational modes. Interaction of other commands and transition between modes will be given. General software architecture and command syntax is presented.


Operation Modes

The AMCS supports 5 modes of operation:

  • digital position
  • digital velocity
  • digital torque
  • analog velocity
  • analog torque

The analog input is placed in the drive. The analog signal is converted in the drive and that value is transferred periodically through the DPRAM to the SCPC. There is a delay of one communication cycle from the analog input signal to the data received in the SCPC. The SCPC converts the analog input data to the appropriate (scaled) values and transfers it back to the drive. Both in the analog and digital SC mode, the drive is in digital mode.


Independently of the current operation mode, each motion sampling period, the SCPC always sends the following data to the drive:

  • position - PCMD
  • velocity - VCMD
  • torque - TCMD

Depending on the current drive operation mode only the relevant values will be taken. The drive always (each communication sample) sends the following data back to the SCPC:

  • feedback position(PFB)
  • feedback torque(TFB)

Changing the modes is done implicitly by issuing MOVE (position), JOG (velocity) or DIGITALTORQUE (torque) commands, or explicitly by the WoMode command.

The three drive modes will be pre-defined using the IDN’s 32-34. Selecting new drive mode is done in the following way:

  • The motion RTK task sends a control-word to the drive each communication cycle. In that control word the bits 7-8 define the drive mode. This bits are changed and the control word is sent to the drive.
  • When the drive successfully finishes the mode change, it returns the new mode in the status word, that is sent periodically from the drive to SCPC.

The transition between modes will be calculated in the drive’s background loop and will take:

  • one communication sample for transitions from Position/Velocity to Torque
  • 3-4 communications samples for transitions from Torque to Position/Velocity


Program Example

Program

attach

Move 1000

Jog 100

sleep 3000

WoMode AVmode

sleep 1000

Jog vfb StartType = Imm

sleep 5000

DigitalTorque 500 StartType = Imm

detach

End Program

Operation modes

In all transitions the command for changing the new drive mode is entered from the RTK at the sample of the motion package exchange. After one of the mode-change commands(see below) is executed and completed the system keeps that mode until the next change is issued.

Digital position

  • The default SC mode.
  • Entered by issuing a MOVE or WoMode DPmode command.
  • The drive takes position and velocity command (PCMD, VCMD) each SCPC motion sample.

Digital velocity

  • Entered by issuing a JOG or WoMode DVmode command.
  • The drive takes velocity command (VCMD) each SCPC motion sample.
  • The velocity is generated by the profiler in the same way as in digital position mode

Digital torque

  • Entered by issuing a DIGITALTORQUE or WoMode DTmode command.
  • The drive takes torque command (TCMD) each SCPC motion sample.
  • The command torque vale is computed changing the value linearly from the initial torque value to the target torque value during the given time (TimeToTorque).

Analog velocity

  • Entered by issuing WoMode AVmode command.
  • Each SCPC motion sampling period the analog input value is taken from the DPRAM scaled by the AnalogVeloctyScale property and returned back to the drive as command velocity.

Analog torque

  • Entered by issuing WoMode ATmode command.
  • Each SCPC motion sampling period the analog input value is taken from the DPRAM scaled by the AnalogTorqueScale property and returned back to the drive as command torque.

Setting a mode (transition between the modes)

Entering the digital position mode

From digital velocity to digital position

According to the current MC rules for the movement commands. If the StartType is Immediate the new movement will be exchanged on-the-fly taking the current position feedback and the current velocity & acceleration command for the 5-samples position prediction, therefore small position jumps can occur - this due to the inability to compute exactly the 5-samples ahead-position. The picture shows the time-position/velocity graphs of the command execution:

MOVE pos StartType=Immediate

entered while the system was in DIGITAL-VELOCITY mode. If the StartType is Super-Immediate then, the initial position will be set to the current position feedback. In this case, no position jump can occur.

Axy;OPmodes Digital velocity to Digital Position.png

If the movement is not an immediate one, the Motion Manager Task will wait until the current digital torque command finishes. Only when the torque is zero, the current feedback position will be taken for the start position of the next movement pre-calculation. Again, due to the uncertain movements in the torque mode there could be some position jumps. (See 5.11)


Under the assumption that transition from velocity to position mode in the drive doesn’t take more then 1-2 motion samples, there shouldn’t be any visible disturbances during the transition. Also, during the drive mode transition, the velocity & position commands are changed smoothly and sent both to the drive during whole transition process.

Axy;OPmodes From Digital Velocity To Digital Position.png

From digital torque to digital position

According to the current MC rules for the movement commands.

If the StartType is Immediate the new movement will be exchanged on-the-fly taking the current position, velocity and acceleration feedback for the 5-samples position prediction, therefore small jumps in position can occur - this due to the inability to compute exactly the 5-samples ahead-position. The picture shows the time-position/velocity/torque graphs of the command execution:

MOVE pos StartType=Immediate

entered while the system was in DIGITAL-TORQUE mode. If the StartType is Super-Immediate then, the initial position & velocity will be set to the current position & velocity feedback. In this case, no position jump can occur.

If the movement is not an immediate one, the Motion Manager Task will wait until the current digital torque command finishes. Only when the torque is zero, the current feedback position will be taken for the start position of the next movement pre-calculation. Again, due to the uncertain movements in the torque mode there could be some position jumps. (See 5.11)


Axy;OPmodes Digital Torque to Digital Position(Immediate).png

Under the assumption that transition from torque to position mode in the drive doesn’t take more then 2-3 motion samples, there shouldn’t be any visible disturbances. Also, during the transition between the drive modes the torque command is kept constant, while the position & velocity are smoothly changed according to the used profiler. Only when the drive mode transition is completed the system enters the torque-following mode and the TCMD follows the TFB value. (See: 5.7 Following modes).

Axy;OPmodes From Digital Torque to Digital Position.png

From analog velocity to digital position

Only the MOVE commands with StartType=Immediate/Super-Immediate will be accepted, other StartType values will cause an error. A 5-samples constant acceleration prediction based on the feedback position & acceleration and the command velocity will be used for calculating the initial position. Therefore small jumps in position can occur - this due to the inability to compute exactly the 5-samples ahead-position. The picture shows the time-position/velocity graphs of the command execution:

MOVE pos StartType=Immediate

entered while the system was in ANALOG-VELOCTY mode. If the StartType is Super-Immediate then, the initial position & velocity will be set to the current position & velocity feedback. In this case, no position jump can occur.

Under the assumption that transition from velocity to position mode in the drive doesn’t take more then 1-2 motion samples, there shouldn’t be any visible disturbances during the transition. Also, during the drive mode transition the velocity & position commands are changed smoothly and sent both to the drive during whole transition process.

Axy;OPmodes Analog Velocity to Digital Position.png

From analog torque to digital position

Only the MOVE commands with StartType=Immediate/Super-Immediate will be accepted, other StartType values will cause an error. A 5-samples constant acceleration prediction based on the feedback position, velocity & acceleration, will be used for calculating the initial position. Therefore small jumps in position can occur - this due to the inability to compute exactly the 5-samples ahead-position. The picture shows the time-position/velocity/torque graphs of the command execution:

MOVE pos StartType=Immediate

entered while the system was in ANALOG-VELOCTY mode. If the StartType is Super-Immediate then, the initial position & velocity will be set to the current position & velocity feedback. In this case, no position jump can occur.

Under the assumption that transition from torque to position mode in the drive doesn’t take more then 2-3 motion samples, there shouldn’t be any visible disturbances. Also, during the transition between the drive modes the torque command is kept constant, while the position & velocity are smoothly changed according to the used profiler. Only when the drive mode transition is completed the system enters the torque-following mode and the TCMD follows the TFB value. (See: 5.7 Following modes).


Axy;OPmodes Analog Torque to Digital Position.png

Entering the digital velocity mode

From digital position to digital velocity

The motion is continued by entering new movement according to its StartType (Immediate, Super-Immediate, Generator-Completed, In-position), same as in MC. Both modes are profiler-driven, due to the fact that the implementation of digital-velocity mode does not differ from the digital-position mode, except the operation inside drive, the transitions are exactly the same as transitions between MOVE and JOG commands in MC.

From digital torque to digital velocity

According to the current MC rules for the movement commands. If the StartType is Immediate the new movement will be exchanged on-the-fly taking the current velocity & acceleration feedback for calculating the 5-samples ahead velocity value of the next movement, executed in velocity mode. Therefore, small jumps in position can occur - this due to the inability to compute exactly the 5-samples ahead-position. The picture shows the time-velocity/torque graphs of the command execution:

JOG vel StartType=Immediate

entered while the system was in DIGITAL-TORQUE mode. If the StartType is Super-Immediate then, the initial position & velocity will be set to the current position & velocity feedback. In this case, no position jump can occur.

If the movement is not an immediate one, the user-task will wait until the current digital torque command finishes. Only when the torque is zero, the current feedback velocity will be taken for the initial velocity of the next movement pre-calculation. Again, due to the uncertain movements in the torque mode there could be some position jumps.

Under the assumption that transition from torque to velocity mode in the drive doesn’t take more then 2-3 motion samples, there shouldn’t be any visible disturbances. Also, during the transition between the drive modes the torque command is kept constant, while the position & velocity are smoothly changed according to the used profiler. Only when the drive mode transition is completed the system enters the torque-following mode and the TCMD follows the TFB value. (See: 5.7 Following modes).


Axy;OPmodes Digital Torque to Digital Velocity.png

From analog velocity to digital velocity

Only the JOG commands with StartType=Immediate/Super-Immediate will be accepted, other StartType values will cause an error. A 5-samples constant acceleration prediction based on the feedback position & acceleration and the command velocity will be used for calculating the initial position. Therefore small jumps in position can occur - this due to the inability to compute exactly the 5-samples ahead-position. The picture shows the time-velocity graphs of the command execution:

JOG vel StartType=Immediate

entered while the system was in ANALOG-VELOCTY mode. If the StartType is Super-Immediate then, the initial position & velocity will be set to the current position & velocity feedback. In this case, no position jump can occur.

In this case the drive does not change the mode, therefore no transition problems can occur.


Axy;OPmodes Analog Velocity to Digital Velocity.png

From analog torque to digital velocity

Only the JOG commands with StartType=Immediate/Super-Immediate will be accepted, other StartType values will cause an error. A 5-samples constant acceleration prediction based on the feedback position, velocity & acceleration will be used for calculating the initial velocity. Therefore small jumps in position can occur - this due to the inability to compute exactly the 5-samples ahead-position. The picture shows the time-position/velocity graphs of the command execution:

JOG vel StartType=Immediate

entered while the system was in ANALOG-TORQUE mode. If the StartType is Super-Immediate then, the initial position & velocity will be set to the current position & velocity feedback. In this case, no position jump can occur.

Under the assumption that transition from torque to velocity mode in the drive doesn’t take more then 2-3 motion samples, there shouldn’t be any visible disturbances. Also, during the transition between the drive modes the torque command is kept constant, while the velocity is smoothly changed according to the used profiler. Only when the drive mode transition is completed the system enters the torque-following mode and the TCMD follows the TFB value. (See: 5.7 Following modes).

Axy;OPmodes Analog Torque to Digital Velocity.png

Entering the digital torque mode

From digital position to digital torque

According to the current MC rules for the movement commands. The trapeze-‘velocity’ profiler is used. The current torque feedback will be taken for the initial torque value. The picture shows the time-position/velocity/torque graphs of the command execution:

DigitalTorque trq StartType=Immediate

entered while the system was in DIGITAL-POSITION mode.

If the movement (DigitalTorque-command) is not an immediate one, the user-task will wait until the current digital position command finishes. The current feedback torque will be taken for the initial torque of the next movement pre-calculation.

Under the assumption that transition from position to torque mode in the drive doesn’t take more then 1-2 motion samples, there shouldn’t be any visible disturbances. Also, during the transition between the drive modes the torque command is changed according its profiler while the position & velocity are kept on the values of the sample when the change was ordered.

Axy;OPmodes Digital Position to Digital Torque.png

From digital velocity to digital torque

According to the current MC rules for the movement commands. The trapeze-‘velocity’ profiler is used. The current torque feedback will be taken for the initial torque value. The picture shows the time-velocity/torque graphs of the command execution:

DigitalTorque trq StartType=Immediate

entered while the system was in DIGITAL-VELOCITY mode.

If the movement (DigitalTorque-command) is not an immediate one, the user-task will wait until the current digital position command finishes. The current feedback torque will be taken for the initial torque of the next movement pre-calculation.

Under the assumption that transition from velocity to torque mode in the drive doesn’t take more then 1-2 motion samples, there shouldn’t be any visible disturbances. Also, during the transition between the drive modes the torque command is changed according its profiler while the position & velocity are kept on the values of the sample when the change was ordered.


Axy;OPmodes Digital Velocity to Digital Torque.png

From analog velocity to digital torque

According to the current MC rules for the movement commands. The trapeze-‘velocity’ profiler is used. The current torque feedback will be taken for the initial torque value. The picture shows the time-velocity/torque graphs of the command execution:

DigitalTorque trq StartType=Immediate

entered while the system was in ANALOG-VELOCITY mode.

Under the assumption that transition from velocity to torque mode in the drive doesn’t take more then 1-2 motion samples, there shouldn’t be any visible disturbances. Also, during the transition between the drive modes the torque command is changed according its profiler while the position & velocity are kept on the values of the sample when the change was ordered.

Axy;OPmodes Analog Velocity to Digital Torque.png

From analog torque to digital torque

According to the current MC rules for the movement commands. The trapeze-‘velocity’ profiler is used. The current torque feedback will be taken for the initial torque value. The picture shows the time-velocity/torque graphs of the command execution:

DigitalTorque trq StartType=Immediate

entered while the system was in ANALOG-TORQUE mode.

In this case the drive does not change the mode, therefore no transition problems can occur.


Axy;OPmodes Analog Torque to Digital Torque.png

Entering the analog velocity mode

Immediate switching to analog command, no deceleration profile. The smoothness of transition is user’s responsibility. The analog velocity mode is entered by issuing command:

WoMode AVmode

If there is some motion (Move/Jog/DigitalTorque) currently executing or pending it will be canceled.


Axy;OPmodes Digital PVT to Analog VT.png

Entering the analog torque mode

Immediate switching to analog command, no deceleration profile. The smoothness of transition is user’s responsibility. The analog velocity mode is entered by issuing command:

WoMode ATmode

If there is some motion(Move/Jog/DigitalTorque) currently executing or pending it will be canceled.


The explicit mode change (WoMode - command)

Entering digital modes

Operation modes can be changed implicitly and explicitly. The implicit changes are made using the Move/Jog/DigitalTorque commands as described in previous paragraphs. The operation modes can be changed explicitly using the WoMode command. If the desired mode (mode given as an argument of the WoMode command) is one of the digital modes (position, velocity or torque) the mode change is done at the motion end, means at the generator end. In certain cases the generator end doesn’t necessary mean the – no movements.

  • When the movement in digital position mode is executed it can be specified with a non-zero final velocity.
  • When the command torque is zero, in the digital torque mode, the motor could be moving.

From all these reasons when explicitly entering in one of the digital modes the system will automatically execute a kind of automatic-braking procedure(stopping). Namely:

  • When entering the digital position mode the usual stopping profile will be generated using the modal DecMax value.
  • When entering the digital velocity mode the usual stopping profile will be generated using the modal DecMax value.
  • When entering the digital torque mode the system generates a trapeze-profile reducing the command torque to zero during the modal <TimeToTorque> milli-seconds.

From analog velocity to digital position

The current position feedback and the velocity command values will be set as initial values for the stopping profile. The initial acceleration will be set to zero. During the transition between the drive modes the velocity & position values are changed according to the profiler.


From analog torque to digital position

The current position and velocity feedback values will be set as initial values for the stopping profile. The initial acceleration will be set to zero. During the transition between the drive modes the torque command is changed according its source while the position & velocity are changed according to the profiler.


From digital velocity to digital position

The current position feedback and the velocity & acceleration command values will be set as initial values for the stopping profile.


From digital torque to digital position

The current position and velocity feedback values will be set as initial values for the stopping profile. The initial acceleration will be set to zero. During the transition between the drive modes the torque command kept on its initial value(the value at the beginning of the process) while the position & velocity are changed according to the profiler.


From analog velocity to digital velocity

The current position feedback and the velocity command values will be set as initial values for the stopping profile. The initial acceleration will be set to zero.


From analog torque to digital velocity

The current position and velocity feedback values will be set as initial values for the stopping profile. The initial acceleration will be set to zero. During the transition between the drive modes the torque command is changed according its source while the position & velocity are changed according to the profiler.


From digital position to digital velocity

The current position, velocity and acceleration command values will be set as initial values for the stopping profile. During the transition between the drive modes the velocity & position values are changed according tot he profiler. The action is identical to stopping in digital position mode.

From digital torque to digital velocity

The current position and velocity feedback values will be set as initial values for the stopping profile. The initial acceleration will be set to zero. During the transition between the drive modes the torque command kept on its initial value(the value at the beginning of the process) while the position & velocity are changed according to the profiler.


From analog velocity to digital torque

The current torque feedback value will be changed to zero during the modal value of the TimeToTorque property. During the transition between the drive modes the position & velocity values will be kept on its initial values (the value at the beginning of the process) while the torque value is changed according to the profile.


From analog torque to digital torque

The current torque command value will be changed to zero during the modal value of the TimeToTorque property. During the transition between the drive modes the position & velocity values will be kept on its initial values (the value at the beginning of the process) while the torque value is changed according to the profile.


From digital position to digital torque

The current torque feedback value will be changed to zero during the modal value of the TimeToTorque property. During the transition between the drive modes the position & velocity values will be kept on its initial values (the value at the beginning of the process) while the torque value is changed according to the profile.


From digital velocity to digital torque

The current torque feedback value will be changed to zero during the modal value of the TimeToTorque property. During the transition between the drive modes the position & velocity values will be kept on its initial values (the value at the beginning of the process) while the torque value is changed according to the profile.


Properties and Commands

TCMD

Short form <axis>.tcmd
Syntax
Description Command torque value (analog to pcmd). Note: the actual torque value sent to the drive is in percentage of motor continuous stall current (100*MICONT, IDN111).
Data Type double
Range -MICONT*100  +MICONT*100
Default
Units milli Amps
Non-Volatile
Scope Config, task, monitor
Write Access Read Only
Limitations modal-only, Attachment not needed (read only)
Examples  ?tcmd
Cross Reference

TFB

Short form <axis>.tfb
Syntax
Description Feedback torque value. (analog to pfb)
Data Type double
Range -MICONT*100  +MICONT*100
Default
Units milli Amps
Non-Volatile
Scope Config, task, monitor
Write Access Read Only
Limitations modal-only, Attachment not needed (read only)
Examples  ?tfb
Cross Reference

WoMode

Short form WoMode
Syntax Setting: WoMode <axis> <new mode>

Query: ?<axis>.WoMode

Description Sets the operational mode explicitly:

<new mode> 04

DPmode(0) – digital position

DVmode(1) – digital velocity

DTmode(2) – digital torque

AVmode(3) – analog velocity mode

ATmode(4) – analog torque mode* If the current mode is digital then, the mode change occurs at the end of the current movement command (Move, Jog, and DigitalTorque) when the generator completes the motion.

  • The interpreter does not wait the motion end, all succeeding WoMode commands will overwrite the previous value if given during the same movement.
  • If the current mode is analog and the new mode is one of the digital modes, then the mode change occurs immediately, and a profiled change (stopping) of the PVT values is executed to the following rules:
  • to DIGITAL-POSITION mode the axis is stopped using the DecMax value with the initial velocity and position values equal to the current feedback values. At the end the velocity is zero.
  • to DIGITAL-VELOCITY mode the axis is stopped using the DecMax value with the initial velocity and position values equal to the current feedback values. At the end the velocity is zero.
  • to DIGITAL-TORQUE mode the torque is changed to zero value using the nodal value of TimeToTorque for the torque change from its initial value that is equal to the current feedback value to zero torque value.


Data Type integer (when queried)
Range 04
Default 0
Units none
Non-Volatile
Scope Config, task, monitor
Write Access Read/Write
Limitations modal-only, Attachment needed
Examples WoMode DTmode – setting digital mode

?WoMode – querying the current mode

Cross Reference

AnalogTorqueScale

Short form ATS
Syntax <axis>.AnalogTorqueScale
Description Used for computing command torque during analog torque mode (TCMD = AmalogTorqueScale*AIN). Note: the actual torque value sent to the drive is in percentage of motor continuous stall current (100*MICONT, IDN111).
Data Type double
Range minDoublemaxDouble
Default 0
Units miliAmps/(Volt-analog-to-digital conversion unit)

Open Issue: There is a possibility to a hard-soft scale on the Analog Input depending on the drive type that will be used.

Non-Volatile
Scope Config, task, monitor
Write Access Read/Write
Limitations modal-only, Attachment needed
Examples  ?AnalogTorqueScale
Cross Reference

AnalogVelocityScale

Short form AVS
Syntax <axis>.AnalogVelocityScale
Description Used for computing command velocity during analog torque mode (VCMD = AmalogTorqueScale*AIN).
Data Type double
Range minDoublemaxDouble
Default 0
Units RPM/(Volt-analog-to-digital conversion unit)

Open Issue: There is a possibility to a hard-soft scale on the Analog Input depending on the drive type that will be used.

Non-Volatile
Scope Config, task, monitor
Write Access Read/Write
Limitations modal-only, Attachment needed
Examples  ?AnalogVelocityScale
Cross Reference

TimeToTorque

Short form none
Syntax <axis>.TimeToTorque
Description Defines the time needed to change the torque from an initial value to the value given in the Torque command.
Data Type integer
Range (1motion cycle)maxInt
Default (1motion cycle)
Units milli-seconds
Non-Volatile
Scope Config, task, monitor
Write Access Read/Write
Limitations Modal/Nodal, Attachment needed
Examples  ?TimeToTorque

DigitalTorque 100 TimeToTorque = 1000

Cross Reference DigitalTorque

TimeTorque

Short form none
Syntax <axis>.TimeTorque
Description Time when the deceleration (torque decrease towards zero) is started, counting from the end of the torque increase. Same as MC TimeJog.
Data Type integer
Range -1,0maxInt
Default -1
Units milli-seconds
Non-Volatile
Scope Config, task, monitor
Write Access Write
Limitations Nodal-only, Attachment needed
Examples DigitalTorque 100 TimeTorque = -1
Cross Reference DigitalTorque

Move

Short form
Syntax same as MC
Description Command* Automatically enters DIGITAL-POSITION mode.
  • If the SC is in one of the analog modes only StartType=Immediate is allowed. Any other StartType value will cause an error.


Data Type
Range
Default
Units
Non-Volatile
Scope
Write Access
Limitations
Examples
Cross Reference

JOG

Short form
Syntax same as MC
Description Command* Automatically enters DIGITAL-VELOCITY mode.
  • If the SC is in one of the analog modes only StartType=Immediate is allowed. Any other StartType value will cause an error.


Data Type
Range
Default
Units
Non-Volatile
Scope
Write Access
Limitations
Examples
Cross Reference

DigitalTorque

Short form DTorque
Syntax DigitalTorque <axis> <Torque Value> {TimeToTorque=<time>} <TimeTorque> <StartType=<same as MC>}
Description Command:

Similar to the MC jog command with automatic scaling of the profiler-velocity to torque. Automatically enters the SC to digital torque mode.

<Torque Value> Value of the target torque in mA, if greater then MICONT*100 (IDN111) sting it to this value with sending a note to the user.

TimeToTorque – time needed to reach the target torque value from the initial torque value (See Properties).

TimeTorque – time of the torque command duration, if set to –1 (default) endless torque command. (Same as TimeJog, see properties)

If the SC is in one of the analog modes only StartType=Immediate is allowed. Any other StartType value will cause an error.

Non-Volatile
Scope
Write Access
Limitations Need attachment
Examples DigitalTorque 100
Cross Reference

Constants

DPmode(0) – digital position

DVmode(1) – digital velocity

DTmode(2) – digital torque

AVmode(3) – analog velocity mode

ATmode(4) – analog torque mode


Side effects

Following error detection

  • The following error is checked only in the digital position mode.

Gearing/Camming

  • Gearing/Camming is allowed only in digital position mode, trying to set slave property while not in digital position mode will cause an error. Also trying to change mode from digital position to some other modes while Gearing/Camming will cause an error. This is true for the mode of the slave axis only, the master axis mode can be freely defined.

isMoving

  • The isMoving flag will be set to according to the executing movement command (MOVE/JOG/DTORQUE) as in MC. In analog modes it is set to –2 (-1 slave, 0/1/2/3 – move).

isSettled

  • The isSettled flag will be set to according to the executing movement command (MOVE/JOG/DTORQUE) as in MC. In analog modes it is set to 0.

Attachment/Detachment

  • Detach will wait the program until the end of movement, means isMoving = 0.
  • The analog modes set the axis attached to the executing task (or monitor) until the mode is changed to a digital one.
  • This also means that WoMode AVmode command executed from a monitor implicitly attaches the axis to the monitor and that no other task can attach/move the axis until the mode isn’t changed to a digital one.

Homing

  • Homing is allowed only in digital position mode. If the user tries to execute it in other modes or tries to set other modes during the home an error will be returned.

Following modes

  • When the SC is in one of the position or velocity modes the TCMD value will be equal to the TFB returned from the drive (torque following).
  • When the SC is in one of the torque modes the PCMD & VCMD will have the feedback values, i.e., like in position-following mode.
  • When the SC is in the digital velocity modes the PCMD is calculated by the profiler generating the velocity.
  • When the SC is in the analog velocity mode the PCMD is equal to the PFB (position following).

Transition Timeout

If the drive doesn’t succeed in changing mode after a predefined number of samples a fatal-error is sent to the error-handler.

Stop/Proceed

Stop command

  • Digital Position mode – the stop command works according to the same rules as in MC, generates profile according to the current modal value of DecMax.
  • Digital Velocity mode – the stop command works according to the same rules as in MC, generates profile according to the current modal value of DecMax.
  • Digital Torque mode – the torque is linearly reduced to zero, the time of the torque reduction is defined by the modal value of TimeToTorque property.
  • Analog Velocity mode – The system changes its mode to Digital-Velocity and executes the stop command according to the same rules as in MC, generates profile according to the current modal value of DecMax. There will be no movements in the proceed buffers. The previous mode will be stored.
  • Analog Velocity mode – The system changes its mode to Digital-Torque and executes the stop command according reducing the torque linearly to zero, the time of the torque reduction is defined by the modal value of TimeToTorque property. There will be no movements in the proceed buffers. The previous mode will be stored.

For all modes:

After executing the stop command the attachment behavior and the behavior of all movement commands (Move/Jog/DigitalTorque) is the same as in MC (returning error and pending commands).

Proceed command

The proceed command behaves as in the MC it releases the interpreter and re-activates the movement commands previously stored in the proceed buffers. If the operational mode before the execution of the last stop command was an analog one such mode will be re-activated. The stored modes will be not buffered. New stop command overrides the old stored modes in the same ways as the motion buffer override each other on subsequent stop commands.

The ProceedType = CLEAR(3) sets the system to its default state (DIGITAL-POSITION) mode


Blending

Blending between different modes will be disabled. If two commands of different operation modes are blended, the system will automatically disable the bled functionality without notifying the user and the motions will be executed as if they were entered with no blending option(cp=0)


Waiting for the motion end

In cases of changing the axis mode from digital velocity or torque to digital position by a MOVE command that is not immediate the system will wait for ending the current movement and then, it will execute the pre-calculation of the MOVE command. The waiting occurs in the Motion Manager which effectively prevents other movements to be processed. In case of the single-axis movement it is not a problem because there are no other movements. In case of a multi-axes system this can cause a problem. The other possibility is to make the waiting in the context of the user-task, then there is a problem when the movement is issued from the monitor where waiting is not allowed.(See 3.1.1, 3.1.2 )


Motion properties

Property position velocity torque
Absolute active active active
Acceleration active active not-relevant
Accelerationfactor active active not-relevant
AccelerationMax active active not-relevant
ActiveCam active not-relevant not-relevant
AnalogVelocityScale not-relevant active not-relevant
AnalogTorqueScale not-relevant not-relevant active
AxisName active not-relevant not-relevant
CamCycle active not-relevant not-relevant
CamIndex active not-relevant not-relevant
CamOffset active not-relevant not-relevant
CamValue active not-relevant not-relevant
Capture active active active
CaptureInput active active active
CapturePolarity active active active
Decceleration active active not-relevant
DeccelerationMax active active not-relevant
Direction active active not-relevant
Displacement active not-relevant not-relevant
FirstCam active not-relevant not-relevant
FollowingMode active always on always on
GearRatio active not-relevant not-relevant
IsMoving active active active
IsSetteled active isMoving!=0 isMoving!=0
Jerk active active not-relevant
JerkFactor active active not-relevant
JerkMax active active not-relevant
MasterSource active not-relevant not-relevant
Motion active active active
PositionFactor active not-relevant not-relevant
PositionCommand active pfb pfb
PositionError active active active
PositionErrorMax active not-relevant not-relevant
PositionErrorSettle active not-relevant not-relevant
PositionExternal active active active
PositionExternalFactor active not-relevant not-relevant
PositionFactor active not-relevant not-relevant
PositionFeedback active active active
PositionMax active active active
PositionMaxEnable active active active
PositionMin active active active
PositionMinEnable active active active
PositionRollover active active active
PostionRolloverEnable active active active
PositionTogo active disabled disabled
ProceedType active active active
RTCB1 active active active
RTCB1_Mode active active active
RTCB2 active active active
RTCB2_Mode active active active
RTSB1_Mode active active active
RTSB2_Mode active active active
Simulated active active active
Slave active disabled disabled
SlaveLag active not-relevant not-relevant
SmoothFactor active active not-relevant
StartType active active active
StopType active active active
TimeJog not-relevant active not-relevant
TimeSettle active not-relevant not-relevant
TimeSettleMax active not-relevant not-relevant
TimeTorque not-relevant not-relevant active
TimeToTorque not-relevant not-relevant active
TorqueFeedback active active active
TorqueCommand tfb tfb active
VelocityCommand active active vfb
VelocityCruise active active not-relevant
VelocityExternal active active active
VelocityExternalFactor active active active
VelocityFactor active active active
VelocityFeedback active active active
VelocityFinal active active not-relevant
VelocityJog active active not-relevant
VelocityMax active active not-relevant
VelocityOverride active active not-relevant
VelocityOverspeed active active active
Wrap active active active

Legend:

active - functions as usual

not-relevant - can be assigned and queried but does not affect anything

disabled - not functioning, when assigned or queried returns an error

new - the property doesn’t exist in MC

Appendix (future features)

Velocity following error

Checking the difference between velocity command and velocity feedback against a given threshold (max).

Torque following error

Checking the difference between torque command and torque feedback against a given threshold (max).

Additive torque

To add torque value together with position/velocity. The drive supports such an option but the SC should run two profilers in parallel (one for the position/velocity & one for the torque)

Analog superposition