Point Redundancy is a flag that indicates the type of solution calculated by the Motion Controller to reach a specific point in space.
If a point was declared, for example; DIM SHARED PNT AS LOCATION OF XYZR, then the following sub-fields exists;
PNT.ARM, PNT.ELBOW, PNT.WRIST, PNT.TURN1, ..., PNT.TURN6

There are 3 ways to obtain Point Redundancy:
1. By using the property PNT.ARM (for SCARA only):

  • 0 - Auto (closest solution), the default value
  • 1 - Lefty (J2.PCMD < 0)
  • 2 - Righty (J2.PCMD > 0)

2. Assighnments:

  • PNT = Scara.HERE or PNT = Scara.SETPOINT
  • In that case, flags are automatclly set during the assignment.

3. Constant Assignment:

  • PNT = #{X,Y,Z,R;<'flag'>} by using the ";" separator between the location and the flag.
  • Note: in the previous format, all flags were set to zero (for more information refer to 'SEE ALSO' section).

Syntax

Dim Shared PNT as Location Of XYZR

PNT = #{X,Y,Z,R;<'flag'>}

Availability

FirmWare 0.4.20.1 and newer

Type

long

Range

0-2

Default

0 - Auto flag

Scope

Read/Write, Configuration, Task, Terminal

Limitations

1. There are no flags used when declaring location as a joint point (DIM SHARED JPNT AS JOINT OF XYZR).
2. Expressions are only allowed when all flags are equal or one of them is non-AUTO;

  • for example, if A = #{X1,Y1,Z1;1} and B = #{X2,Y2,Z2;1}, the expression PNT = A+B is valid