MC-Basic:axis.COMPPOSITIONCOMMAND

From SoftMC-Wiki
Revision as of 14:02, 15 September 2014 by Miborich (talk | contribs)
Jump to: navigation, search

The Actual Corrected Position command query .This property returns the position command generated by the motion profiler after the correction value added to it. When no correction is used (i.e. all the comp tables involves the axis as its target is inactive) then this value would be identical to the Axis.Pcmd.

POSITIONCOMPENSATION.PNG
Signal-flow diagram of position values. The generated Position Command is corrected by the position backlash value and the compensation table value. These form the CompPositionCommand which is later multiplied by PositionFactor to translate it into drive position units (counts) - CCMD. The corresponding value of CCMD is returned from the drive as CFB, divided by PositionFactor and read as CompPositionFeedback value. The actual PositionFeedback value is compensated back (subtracted) with compensation table value.

Short form

<axis>.CompPCMD

Syntax

?<axis>.CompPositionCommand

Availability

Since Version 3.6.20

Type

Double

Range

± MaxDouble

Units

User Axis position units as given by <axis>.PositionFactor

Scope

Task and Terminal

Limitations

Read Only

Examples

<comp>.SourceData[1][15] = 120.0 position on axis

<comp>.TargetData[1][15] = 0.125   correction value regarding SourceData position

Move <axis> 120.0

Print <axis>.PCmd

--> 120.0     (it’s the “expected user value”)

Print <axis>.CompPCmd

--> 120.125  (it’s the “real value”)

See Also