MC-Basic:axis.UserFollowingMode
The type of the Following mode can be defined by setting different values into FOLLOWINGMODE. The query on this property returns the internal state:
1 - The drive is in Following mode
\
0 - Indicates on a regular working mode
The current property comes to help the user to query what is the following-mode type and not indication on the current working mode.
Short form
<axis>.UserFmode
Syntax
?<axis>.UserFollowingMode
Availability
From ver 4.10.x
Type
Long
Range
0 –( Default ) No user following mode
2 - Soft user following mode, keeps PositionCommand equal to PositionFeedback
-2 - User following by (PCMD = PCMD0 )- relevant only when drive status BIT3 is set. Exiting this type of following mode is with setting PCMD using IDN47 AT cyclic telegram.
-3 - User following by (PCMD = PCMD0 )- relevant only when drive status BIT3 is set. Exiting this type of following mode is with setting PCMD using drive PFB AT cyclic telegram.
Units
Integer
Default
0
Scope
Configuration, Task or Terminal
Limitations
- Read only
- Valid for axis only
Examples
?X_Axis.FollowingMode