{{MC-Basic |SHORT FORM= |SYNTAX= ?<axis>.CountExtRollover |AVAILABILITY=From ver 4.7.13 |DESCRIPTION=Axystems:CountMinMax
Setting zero reset the counter.
This property indicates the number of rollovers that were passed in the drive. |TYPE= intger |RANGE= min-max integer |UNITS= int |DEFAULT= none |SCOPE=Configuration, Task or Terminal |LIMITATIONS= Axis only , Can be set only when the drive is disabled. |EXAMPLE= |SEE ALSO=
- axis.CountMax
- axis.CountMin
- axis.CountExtMax
- axis.CountExtMin
- axis.CountRollOver
- [[Axystems:Infinte_Axes | Infinite Axes]
Issue 5339 }}