MC-Basic:element.MOTIONSTATUS
This read-only property queries the motion status of an element. The element status is returned every SERCOS communication cycle and comprises of 32 bits:
Bit [0] prf_stop
Bit [1] prf_start
Bit [2-3] prf_oper
Bit [4-5] prf_mode
Bit [6-7] prf_type
Bit [8-11] acc_phase
- (Ax.motionstatus shr 8) band 0b1111
- 0 = element acceleration is increasing
- 1 = In position<
- 2 = acceleration decrease
- 3 = zero acceleration
- 4 = Trapez Linear acceleration is increasing
- 5 = Trapez acceleration satruration
- 6 = Trapez acceleration decreasing
- 7 = Trapez zero acceleration
Bit [12-14] mot_type
Bit [15] doub_mod
Bit [16] sinprg
Bit [17] group_axes
Bit [18-20] allow_proceed
Bit [21-22] unusedH
Bit [23] imm_exp
Bit [24] imm_chng
Bit [25] stopped
Bit [26] interrupted
Bit [27] pending
Bit [28-30] broken_counter
Bit [31] sing
Syntax
none
Availability
All versions
Type
Long
Range
TBD
Scope
Configuration, Task or Terminal
Limitations
Read-Only
Examples
?(Ax.motionstatus shr 8) band 0b1111