AXY:MC-Basic:axis.TIMEACCMIN

From SoftMC-Wiki
Revision as of 16:01, 13 December 2010 by Arwiebe (talk | contribs) (Created page with '{{MC-Basic |SHORT FORM= <AXIS>.TAccMin |SYNTAX= <AXIS>.TAccMin=<''numeric expression''> |AVAILABILITY= Versions AMCS 0.4.4.x and higher |DESCRIPTION= Defines minimum accelerat…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Defines minimum acceleration time, if set to 0 the whole feature is switched off.

Short form

<AXIS>.TAccMin

Syntax

<AXIS>.TAccMin=<numeric expression>

Availability

Versions AMCS 0.4.4.x and higher

Type

integer

Range

0-maxlong

Units

milliseconds

Default

0 – not active

Scope

Task, Terminal

Limitations

Modal/Nodal Read/Write

Examples

A1.timeaccmin = 500

A1.timedecmin = 1000

A1. timeofshortmotions = 200