MC-Basic:SYSTEM.PIPEMODE

From SoftMC-Wiki
Revision as of 16:01, 13 December 2010 by Arwiebe (talk | contribs) (Created page with '{{MC-Basic |SHORT FORM= Sys.PMode |SYNTAX= Sys.PMode = ''<expression>'' ? Sys.PMode |AVAILABILITY= Versions 3.6.20 and higher |DESCRIPTION= This property defines motion pipe …')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

This property defines motion pipe mode type. Pipe mode types:

0 – Pipe mode is inactive

1 – Position pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[8] contain position commands for the respective axes.

2 – Position & Velocity pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[8] contain position and velocity commands for the respective axes.

Sys.VIn contains drive’s operation mode information.

Sys.Vin variable.defines  the Operation modes for each axis are set 0 or  1.

The valid operation modes values are :

0 – Position operation mode

1 – Velocity  operation mode

Short form

Sys.PMode

Syntax

Sys.PMode = <expression>

? Sys.PMode

Availability

Versions 3.6.20 and higher

Type

Long

Range

0 , 1 or 2

Default

0

Scope

Config, Task or Terminal

Limitations

Engaging sys.pipemode (1 or 2) is not allowed during motion.. To leave pipemode, all axes pipemode property should be off.

Examples

Sys.PMode = 1

?Sys.PMode

See Also