AXY:MC-Basic:group.POSITIONERRORDELAY

From SoftMC-Wiki
Revision as of 16:00, 13 December 2010 by Arwiebe (talk | contribs) (Created page with '{{MC-Basic |SHORT FORM= ''<group>''.PEDel |SYNTAX= ''<group>''.PositionErrorDelay = ''<value>''<br> ?''<group>''.PositionErrorDelay |AVAILABILITY= All versions |DESCRIPTION=…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

This property returns the number of  SERCOS cycles delay detween a position command and the position feedback for the calculation of the position error.

If using micro interpolation on the drive, this delay may change from 2 cycles (no micro interpolation) to 3 (with micro interpolation).

Explicitly change this property when changing the micro interpolation mode on the drives. Otherwise, erroneous position error is calculated.

Short form

<group>.PEDel

Syntax

<group>.PositionErrorDelay = <value>

?<group>.PositionErrorDelay

Availability

All versions

Type

Long

Range

1 to 9

Units

SERCOS cycle times

Default

2 (Assuming no microinterpolation)

Scope

Task or Terminal

Limitations

To set the value within a task, the group must be attached to that task (using the ATTACH command) and disabled (Group.ENABLE = 0 )

Examples

G1.PEDel = 3