MC-Basic:axis.MASTERSYNC

From SoftMC-Wiki
Revision as of 16:00, 13 December 2010 by Arwiebe (talk | contribs) (Created page with '{{MC-Basic |SHORT FORM= ''<axis>''.MSYN |SYNTAX= ?''<axis>''.MasterSync |AVAILABILITY= All versions |DESCRIPTION= MASTERSYNC is a read-only axis property indicating whether th…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

MASTERSYNC is a read-only axis property indicating whether the speed of the slave is synchronized to the master. This flag is cleared when gearing is enabled and set when synchronization is achieved. Synchronization is achieved when the slave velocity is equal to the master velocity for the first time.

Short form

<axis>.MSYN

Syntax

?<axis>.MasterSync

Availability

All versions

Type

Long

Range

0 or 1

Default

0

Scope

Configuration, Task or Terminal

Limitations

Read-Only

Examples

If X_Axis.MasterSync Then
       Move X_axis x_axis.SlaveLag Absolute = 0

See Also