SimulatedAxes

From SoftMC-Wiki
Revision as of 11:46, 8 February 2011 by Anonymous (talk) (Created page with "= Simulated Axes = An axis can be declared simulated by setting <axis>.simulated to '''1'''. Simulated axis returns the same number of cou…")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Simulated Axes

An axis can be declared simulated by setting <axis>.simulated to 1.

Simulated axis returns the same number of counts in feedback (CFB) as was given by command (CCMD).

NOTE-Info.svgNOTE
Position error (PE) of a simulated axis is not always zero. The non zero value can be due to:
  • Integer to float conversion (especially with very small PFAC) values.
  • Inadequate PositionErrorDelay value. Default propagation delay in simulated axes is 2.


NOTE-Info.svgNOTE
Starting from firmware version 4.7.2 propagation delay of a simulated axes will be accessible through these two user functions:
import_c sercSetSimulDelay(byval as long  , byval as long  ) as long
import_c sercGetSimulDelay(byval as long  , as long ) as long