Limit Switch feature

From SoftMC-Wiki
Revision as of 09:31, 16 August 2017 by Itay (talk | contribs) (new page)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

The Limit Switches digital inputs for each axis should be defined in ServoStudio. There are 2 options for defining the limit switches:


  1. Drive Configuration Limits Hardware Position Limits
    Choose the corresponding digital input to each limit switch:
    LSF 1.png

  2. Drive Configuration Digital I/Os Digital Inputs
    Choose the negative and positive limit switch (6 and 5) from the list to the corresponding digital inputs:
    LSF 2.png