This is a tutorial for first configuration of SoftMC with SoftMI thru HMIStudio


Creating project and adding network components

Open new project:
File:HMI1.png

At the left side bar - "Graph Element Window" select HMI tab, and choose HMI type.


HMI2.png

At the left side bar - "Graph Element Window" select PLC tab, and choose controller / PLC type.
Drag and drop in center window:

HMI3.png

At the left side bar - "Graph Element Window" select Connector tab, and choose communication type.
In this example I choose Ethernet (TCP)
Drag and drop in center window:

HMI4.png

At the pop up window - "Network Device Setting" press "Add".
Set HMI IP, and choose correct Comm Protocol:

HMI5.png

Press "Add" again, and set SoftMC IP and comm protocol:

HMI6.png

After adding both HMI and PLC this is the final display:

HMI7.png

Double click the HMI for access extra Attribute configure:

HMI8.png

Importing Parameters file (CSV)

SoftMC Modbus Configurator is generating CSV file containing the project parameters and their Modbus addresses.

Generating CSV file with Modbus Configurator [[1]]

Importing the CSV file to HMIStudio:
Go to “Project Database” tab in “Graph Element Window”, and choose “Address Tag”:

HMI9.png

Import the CSV File:

HMI10.png

HMI11.png


Build and design the interface

Operations in HMI screen are carried out thru Components.
In this components user can execute SoftMC Functionality, read and write data.

To enter screen design window, Right click on HMI, and “Edit”:

HMI12.png

Basic components are located at "Graph Element Window" at "PLC Parts":

HMI13.png

Drag and drop required component to center window (HMI Screen).
When doing so, arttribute of the component will open:

HMI14.png

Check the box “Use Address Tag”. Then Parameters from CSV file will shown in “Addr. Type” – only if their type fit (for example this is “Bit” switch, so only “EN_BIT1” is shown because it is the only bit in CSV file.
After finish configuration and pressing OK, another left click on screen to place the switch.

Component Attribute

It is important to fully configure the component, in means of data tpye, size, operation, etc.
For example, when adding number display, make sure “Data width” is according to what configured in softMC Modbus configurator:

HMI15.png

“Word” is 16bit
In SoftMC:
“Short” = 16bit
“long” = 32bit
So if chosen parameter as “long”, choose DWORD (double word).