AXY:MC-Basic:group.JERKMAX
Revision as of 08:51, 22 May 2014 by Miborich (talk | contribs) (Miborich moved page Axystems:MC-Basic:group.JERKMAX to MC-Basic:group.JERKMAX: Global renaming of Axystems: namespace into (Main):)
Defines the maximum allowed jerk. If the trajectory generator issues a JERK command higher than JERKMAX, the system sets the value to JERKMAX and notifies you.
Short form
<group>.JMax
Syntax
<group>.JerkMax = <expression>
?<group>.JerkMax
Availability
All versions
Type
Double
Range
Greater than 0
Units
User axis jerk units
Default
50
Scope
Configuration, Task or Terminal
Limitations
JERKMAX has an effect only if SMOOTHFACTOR is set to -1. To set the value within a task, the group must be attached to that task (using the ATTACH command).
Examples
XyTable.JMax=1.2