This property sets the acceleration rate of the motion profile. When executing a motion command, ACCELERATION should be less than or equal to ACCELERATIONMAX. If it is greater, the motion is executed using the ACCELERATIONMAX value. This property can be used inside a motion command to override the permanent value.

Short form

<group>.Acc

Syntax

<group>.Acceleration = <expression >

?<group>.Acceleration

Availability

All versions

Type

Double

Range

Greater than 0

Units

User group acceleration units, as given by <group>.ACCELERATIONFACTOR

Default

500

Scope

Configuration, Task or Terminal

Limitations

The ratio between jerk and acceleration is limited by the following relation:
       Jerk/Acc < 0.9 * p/5T

where T is the sample time in seconds. For a cycle time of 2 msec, this value is 282.74. Use SMOOTHFACTOR to have jerk calculated automatically.

To set the value within a task, the group must be attached to that task (using the ATTACH command).