MC-Basic:SYSTEM.PIPEMODE

From SoftMC-Wiki
Revision as of 09:28, 12 June 2017 by Itay (talk | contribs)
Jump to: navigation, search
Language: [[::MC-Basic:SYSTEM.PIPEMODE|English]]  • [[::MC-Basic:SYSTEM.PIPEMODE/zh-hans|中文(简体)‎]]

This property defines motion pipe mode type. Pipe mode types:

0 – Pipe mode is inactive

1 – Position pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[128] contain position commands for the respective axes.

2 – Position & Velocity pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[128] contain position and velocity commands for the respective axes.

3 - Velocity-only pipe-mode. Sys.HostDouble[1]…Sys.HostDouble[128] contain velocity commands for the respective axes.

4 - TORQ

Short form

Sys.PMode

Syntax

Sys.PMode = <expression>

? Sys.PMode

Availability

Since Version 3.6.20

Type

Long

Range

0 , 1, 2, 3 or 4

Default

0

Scope

Config, Task or Terminal

Limitations

  • Engaging sys.pipemode (1 or 2) is not allowed during motion. To leave pipemode, all axes pipemode property must be off.
  • Read only

Examples

Sys.PMode = 1

?Sys.PMode

See Also