AXY:MC-Basic:group.BLENDINGFACTORPREVIOUS

From SoftMC-Wiki
Revision as of 08:50, 22 May 2014 by Miborich (talk | contribs)
Jump to: navigation, search

The BF of the previous motion meant to be applied between the previous motion and the current one. The meaning of the range between 0 and 100 is the same as with BF If no such overwriting is desired BFPrev must be set to -1. For more description see also: Blending Behavior

Short form

BFPrev

Syntax

?<group>.BlendingFactorPrevious

<group>. BlendingFactorPrevious = <value>

Type

Double

Range

-1 to 100

Units

Percents of the segments length

Default

-1 (not active)

Scope

Task or Terminal

Limitations

Mixed profiler types are not valid , Modal/Nodal

Examples

G1.BlendingFactorPrevious= 10

?G1.BlendingFactorPrevious

See Also