MC-Basic:pls.PLSOUTPUT

From SoftMC-Wiki
Revision as of 08:36, 22 May 2014 by Miborich (talk | contribs)
Jump to: navigation, search

This property sets or queries the output associated with a PLS.

Short form

<pls>.Pout

Syntax

<pls>.PlsOutput = <system output>

?<pls>.PlsOutput

Availability

All versions

Range

Digital outputs: System.DOut.1 to 20

Virtual outputs: System.VOut.1 to 32

Default

The output associated with the PLS is defined when the PLS is declared (use COMMON SHARED <name> AS PLS).

Scope

Configuration, Task or Terminal

Limitations

The output is set only when the PLS is disabled.

The hardware assisted PLS  works with System.DOut from 1 to 8

Examples

PLS1.Pout = System.DOut.5

?PLS1.PlsOutput                                         ‘returns “System.DOut.5”

See Also