MC-Basic:axis.UserFollowingMode

From SoftMC-Wiki
Revision as of 13:21, 19 March 2014 by Lisa (talk | contribs)
Jump to: navigation, search

The type of the Following mode can be defined by setting different values into FOLLOWINGMODE. The query on this property returns the internal state:

1 - The drive is in Following mode

0 - Indicates on a regular working mode

The current property comes to help the user to query what is the following-mode type and not indication on the current working mode.

Short form

<axis>.UserFmode

Syntax

?<axis>.UserFollowingMode

Availability

From ver 4.10.x

Type

Long

Range

0 – (Default) No user following mode
2 – Soft user following mode, keeps PositionCommand equal to PositionFeedback
-2 – User following by (PCMD = PCMD0). Relevant only when drive status BIT3 is set. Exit this type of following mode by setting PCMD using IDN47 AT cyclic telegram.
-3 – User following by (PCMD = PCMD0). Relevant only when drive status BIT3 is set. Exit this type of following mode by setting PCMD using drive PFB AT cyclic telegram.

Units

Integer

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • Read only
  • Valid for axis only

Examples

?X_Axis.FollowingMode

See Also