MC-Basic:axis.TIMEOFSHORTMOTIONS

From SoftMC-Wiki
Revision as of 12:01, 19 March 2014 by Lisa (talk | contribs)
Jump to: navigation, search

Defines the lower threshold below which TACCMIN and TDECMIN no longer affect motion. If the actual values of acceleration (or deceleration) time is below this limit, the entire excitation-limiting algorithm (TACCMIN and TDECMIN) is switched off.

CAUTION.svgCAUTION
The value of TSHORT is compared to acceleration/deceleration time only, and not to the entire duration of movement. Therefore, long movements with a long cruise-velocity phase and short acceleration/deceleration times could trigger the switch-off of the excitation-limiting algorithm. For best results, use small values (1—4 ms).


NOTE-Info.svgNOTE
Setting one of TACCMIN, TDECMIN or TSHORT to 0, completely disables the entire timing feature (excitation-limiting algorithm)

Short form

<axis>.TSHORT

Syntax

<axis>.TSHORT=<numeric expression>

Availability

Versions AMCS 0.4.4.x and higher

Type

Long

Range

0 to maxlong

Units

milliseconds (ms)

Default

0 – Not active

Scope

Task, Terminal

Limitations

Modal/Nodal Read/Write

Examples

A1.timeaccmin = 500

A1.timedecmin = 1000

A1.timeofshortmotions = 200