Defines minimum acceleration time, if set to 0 the whole feature is switched off.

Short form

<axis>.TAccMin

Syntax

<axis>.TAccMin=<numeric expression>

Availability

Versions AMCS 0.4.4.x and higher

Type

integer

Range

0-maxlong

Units

milliseconds

Default

0 – not active

Scope

Task, Terminal

Limitations

Modal/Nodal Read/Write

Examples

A1.timeaccmin = 500

A1.timedecmin = 1000

A1. timeofshortmotions = 200