This query returns the state of the data recorder. The following values are returned:
0 - recorder undefined and inactive.
1 - Recorder is defined, but inactive. (The RECORDON command is needed to activate it.)
2 - Recording is in progress (Data acquisition process after RECORDON was given.)
3 - Recording suspended. (RECORDOFF command issued.)
4 - Data acquisition completed automatically. Recorder is still defined. (RECORDCLOSE command needed to flush the data to the disk.)
Syntax
?Recording
Availability
All versions
Type
Long
Range
0 to 4
Scope
Task or Terminal
Limitations
Read-Only
Examples
?Recording