MC-Basic:axis.MOTIONBUSVELOCITYBASE

From SoftMC-Wiki
Revision as of 11:37, 12 December 2013 by Miborich (talk | contribs)
Jump to: navigation, search

Used for scaling of Motion-Bus velocity command (SERCOS: IDN37 and IND36, EtherCat: PDO 0x6081) according to:

velocity_in_motion_bus_units = velocity_per_ms* (MotionBusVelocityScale * period + MotionBusVelocityBase)

NOTE-Info.svgNOTE
In order to send velocity in counts per ms following values should be set:
MotionBusVelocityScale = 0
MotionBusVelocityBase = 1

Short form

none

Syntax

<axis>.MotionBusVelocityBase = <value>
?<axis>. MotionBusVelocityBase

Availability

4.2.x

Type

Long

Range

0 ... + MAXL

Default

0

Scope

Configuration, Task or Terminal

Examples

Axis1.MotionBusVelocityBase = 256