This property is used to specify the time for which a JOG command must execute. After the specified time has passed, the axis stops. The value -1 is used to indicate that the JOG has no time limit. The time is specified within a JOG command..

Short form

<axis>.TJog

Syntax

Jog <axis> <Jog velocity value> {TimeJog=

Availability

All versions

Type

Double

Range

-1, 0 to MaxDouble

Units

Milliseconds

Default

-1

Scope

Configuration, Task or Terminal

Limitations

The JOG time should be an integer multiple of the SERCOS cycle time. If it is not, the actual time is rounded up to the nearest integer multiple of the SERCOS cycle time, and a message is given. The JOG command is executed. To set the value within a task, the axis must be attached to that task (using the ATTACH command).

Examples

JOG Xaxis 200 TimeJog=20