AXY:MC-Basic:group.BLENDINGFACTORPREVIOUS
The BF of the previous motion meant to be applied between the previous motion and the current one. The meaning of the range between 0 and 100 is the same as with BF If no such overwriting is desired BFPrev must be set to -1.
Short form
BFPrev
Syntax
?<group>.BlendingFactorPrevious
<group>. BlendingFactorPrevious = <value>
Type
Double
Range
-1 to 100
Units
Percents of the segments length
Default
-1 (not active)
Scope
Task or Terminal
Limitations
Mixed profiler types are not valid , Modal/Nodal
Examples
G1.BlendingFactorPrevious= 10
?G1.BlendingFactorPrevious