AXY:MC-Basic:group.BLENDINGFACTOR

From SoftMC-Wiki
Revision as of 09:19, 26 May 2014 by Miborich (talk | contribs)
Jump to: navigation, search

Percentage of the movement’s length that will be not blended with the next movement.

0% – blending of second movement started from the beginning of the first one .

100% – blending of second movement started from the end of the first one (NO BLENDING) .

For more description see also: Blending Behavior

Syntax

?<group>.BlendingFactor
<group>. BlendingFactor  = <value>

Availability

Since Version 3.6.20

Type

Double

Range

0 to 100

Units

Percents of the segments length

Default

100 (no blending)

Scope

Task or Terminal

Limitations

Mixed profiler types are not valid , Modal/Nodal

Example             Group1. BlendingFactor= 10