Difference between revisions of "AXY:PLS On/Off delay"
(Added more information) |
(Type - double , added formula) |
||
Line 5: | Line 5: | ||
= Solution offered = | = Solution offered = | ||
The solution is by different timing delays that will be define for enable and disable. This timing will be taken into consider when calculating the timing when the PLS has to be set. Again if the disable timing is Tdis then the PLS has to be set Tdis before the original PLS position is reached. | The solution is by different timing delays that will be define for enable and disable. This timing will be taken into consider when calculating the timing when the PLS has to be set. Again if the disable timing is Tdis then the PLS has to be set Tdis before the original PLS position is reached. | ||
+ | The PLS will be calculated <br/> | ||
+ | '''t = (PLSPropagationDelay+Tdis) *1000 + Δt''' | ||
= Limitation = | = Limitation = | ||
Line 11: | Line 13: | ||
= Properties (suggestion)= | = Properties (suggestion)= | ||
=== PLSEnableDelay === | === PLSEnableDelay === | ||
− | *Type = | + | *Type = double |
*Range = 0 - MAXD | *Range = 0 - MAXD | ||
*Units = ms | *Units = ms | ||
Line 21: | Line 23: | ||
=== PLSDisableDelay === | === PLSDisableDelay === | ||
− | *Type = | + | *Type = double |
*Range = 0 - MAXD | *Range = 0 - MAXD | ||
*Units = ms | *Units = ms |
Revision as of 12:04, 28 July 2011
PLS (Programmable Limit Switch) is a mechanism by which a system output is triggered when a specified position is reached.
Contents
The Problem
In application the use of PLS is to control an external device. Can be a situation that there is an asymmetric behavior in enabling and disabling timing of the device. As the indication to PLS is the position without dependency on the external device there can be a case when the disabling (for example) takes longer then enable and finished later then expected. So the PLS has to be set in different timing depend on the enable/disable of the device.
Solution offered
The solution is by different timing delays that will be define for enable and disable. This timing will be taken into consider when calculating the timing when the PLS has to be set. Again if the disable timing is Tdis then the PLS has to be set Tdis before the original PLS position is reached.
The PLS will be calculated
t = (PLSPropagationDelay+Tdis) *1000 + Δt
Limitation
- If the delay time is smaller the the position error delay the time can't be reached. If this option is requested a new look ahead algorithm has to be implement.
- The assumption here is that the enabling-disabling requests are followed each other, so there is no condition for two follow PLS that indicate the same setting (enable/disable).
Properties (suggestion)
PLSEnableDelay
- Type = double
- Range = 0 - MAXD
- Units = ms
- Default = 0
- Scope = Task, Terminal
- Limitation =
- Example = PLSEnableDelay = 4
PLSDisableDelay
- Type = double
- Range = 0 - MAXD
- Units = ms
- Default = 0
- Scope = Task, Terminal
- Limitation =
- Example = PLSDisableDelay = 2
See also
Issue 5151 F: asymmetric plspropagationdelay