Line 24: Line 24:
 
Bit [8-11]  acc_phase
 
Bit [8-11]  acc_phase
  
       This bit sequence indicates the state of the acceleration.<br/>
+
       This bit sequence indicates the state of the acceleration.<br>
  
       Accstatus = (Ax.motionstatus shr 8) band 0b1111<br/>
+
       Accstatus = (Ax.motionstatus shr 8) band 0b1111<br>
  
       0 = element acceleration is increasing<br/>
+
       0 = element acceleration is increasing<br>
  
       1 = In position<br/>
+
       1 = In position<br>
  
       2 = acceleration decrease<br/>
+
       2 = acceleration decrease<br>
  
 
       3 = zero acceleration
 
       3 = zero acceleration

Revision as of 06:18, 17 July 2011

This read-only property queries the motion status of an element. The element status is returned every SERCOS communication cycle and comprises of 32 bits:

Bit [0] prf_stop

Bit [1] prf_start

Bit [2-3] prf_oper

Bit [4-5] prf_mode

Bit [6-7] prf_type

Bit [8-11] acc_phase

      This bit sequence indicates the state of the acceleration.
      Accstatus = (Ax.motionstatus shr 8) band 0b1111

       0 = element acceleration is increasing

      1 = In position
      2 = acceleration decrease
      3 = zero acceleration
      4 = Trapez Linear acceleration is increasing
      5 = Trapez acceleration satruration
      6 = Trapez acceleration decreasing
      7 = Trapez zero acceleration

Bit [12-14] mot_type

Bit [15] doub_mod

Bit [16] sinprg

Bit [17] group_axes

Bit [18-20] allow_proceed

Bit [21-22] unusedH

Bit [23] imm_exp

Bit [24] imm_chng

Bit [25] stopped

Bit [26] interrupted

Bit [27] pending

Bit [28-30] broken_counter

Bit [31] sing

Syntax

none

Availability

All versions

Type

Long

Range

TBD

Scope

Configuration, Task or Terminal

Limitations

Read-Only

Examples

?(Ax.motionstatus shr 8) band 0b1111