This property specifies the conversion factor between the user velocity units and the internal units [counts per msec].
 
This property specifies the conversion factor between the user velocity units and the internal units [counts per msec].
  
In   using VELOCITYFACTOR for a group, the position units are taken from the   POSITIONFACTOR of the axes within the group. The position units must not be   specified in the group’s VELOCITYFACTOR.
+
{{Note|In using VELOCITYFACTOR for a group, the position units are taken from the POSITIONFACTOR of the axes within the group. The position units must not be specified in the group’s VELOCITYFACTOR.}}
  
 
|TYPE=
 
|TYPE=

Revision as of 17:56, 13 December 2010

This property specifies the conversion factor between the user velocity units and the internal units [counts per msec].

NOTE-Info.svgNOTE
In using VELOCITYFACTOR for a group, the position units are taken from the POSITIONFACTOR of the axes within the group. The position units must not be specified in the group’s VELOCITYFACTOR.

Short form

<GROUP>.Vfac

Syntax

<GROUP>.VelocityFactor = <expression>

?<GROUP>.VelocityFactor

Availability

All versions

Type

Double

Range

Greater than zero

Default

1/60000 (for working in units of position units per minute)

Scope

Configuration, Task or Terminal

Limitations

Cannot be changed while axis is enabled or while axis is set up as a master axis.

To set the value within a task, the group must be attached to that task (using the ATTACH command).

Examples

G1.Vfac = 1 / 60000                                   ‘work in per minute

G1.Vfac = 1 / 1000                                     ‘work in per second

See Also