Difference between revisions of "MC-Basic:axis.CAPTUREINPUT"

From SoftMC-Wiki
Jump to: navigation, search
m (1 revision)
m (note template)
Line 12: Line 12:
 
This property is used to set the digital input (on the SERVOSTAR drive) is used as the capture signal. This property takes the values 1, 2, or 3, indicating drive flex-input 1, 2, or 3. These values have keywords IN1, IN2, and IN3. The property sets the value 16 into the relevant IDN on the drive (IDN P123 for IN1; IDN P125 for IN2; IDN P127 for IN3). When the property is queried, the MC checks the drive to see if the flex-input has been set for CAPTURE.
 
This property is used to set the digital input (on the SERVOSTAR drive) is used as the capture signal. This property takes the values 1, 2, or 3, indicating drive flex-input 1, 2, or 3. These values have keywords IN1, IN2, and IN3. The property sets the value 16 into the relevant IDN on the drive (IDN P123 for IN1; IDN P125 for IN2; IDN P127 for IN3). When the property is queried, the MC checks the drive to see if the flex-input has been set for CAPTURE.
  
The property ''<axis>.''CAPTUREINPUT   is replaced in version 3.0 by the properties IN1MODE and IN1.
+
{{Note|The property ''<axis>.''CAPTUREINPUT is replaced in version 3.0 by the properties IN1MODE and IN1.}}
  
 
|TYPE=
 
|TYPE=

Revision as of 17:23, 13 December 2010

This property is used to set the digital input (on the SERVOSTAR drive) is used as the capture signal. This property takes the values 1, 2, or 3, indicating drive flex-input 1, 2, or 3. These values have keywords IN1, IN2, and IN3. The property sets the value 16 into the relevant IDN on the drive (IDN P123 for IN1; IDN P125 for IN2; IDN P127 for IN3). When the property is queried, the MC checks the drive to see if the flex-input has been set for CAPTURE.

NOTE-Info.svgNOTE
The property <axis>.CAPTUREINPUT is replaced in version 3.0 by the properties IN1MODE and IN1.

Syntax

<axis>.CaptureInput = <input>

Availability

All versions

Type

Long

Range

1 to 3

Default

There is no default in the MC. When the property is queried, the MC gets the value from the drive.

Scope

Configuration, Task or Terminal

Examples

a1.CaptureInput = IN2                    'Use IN2 for capture