Percentage of the movement’s length that will be not blended with the next movement.
- 0% – blending of second movement started from the beginning of the first one .
- 100% – blending of second movement started from the end of the first one (NO BLENDING) .
Short form
BFPrev
Syntax
?<group>.BlendingFactorPrevious
<group>. BlendingFactorPrevious = <value>
Type
Double
Range
-1 to 100
Units
Percents of the segments length
Default
-1 (not active)
Scope
Task or Terminal
Limitations
Mixed profiler types are not valid , Modal/Nodal
Examples
G1.BlendingFactorPrevious= 10
?G1.BlendingFactorPrevious