Percentage of the movement’s length that will be not blended with the next movement.
0% – blending of second movement started from the beginning of the first one .
100% – blending of second movement started from the end of the first one (NO BLENDING) .
Syntax
?<group>.BlendingFactor
<group>. BlendingFactor = <value>
Availability
Versions AMCS 0.3.6.20 and higher
Type
Double
Range
0 to 100
Units
Percents of the segments length
Default
100 (no blending)
Scope
Task or Terminal
Limitations
Mixed profiler types are not valid , Modal/Nodal
Example Group1. BlendingFactor= 10