Percentage of the movement’s length that will be not blended with the next movement.

0% – blending of second movement started from the beginning of the first one .

100% – blending of second movement started from the end of the first one (NO BLENDING) .

Syntax

?<group>.BlendingFactor
<group>. BlendingFactor  = <value>

Availability

Versions AMCS 0.3.6.20 and higher

Type

Double

Range

0 to 100

Units

Percents of the segments length

Default

100 (no blending)

Scope

Task or Terminal

Limitations

Mixed profiler types are not valid , Modal/Nodal

Example             Group1. BlendingFactor= 10

See Also