This property defines the action to be taken by the PROCEED command. It may be set as a permanent value, or may be used within a PROCEED command to temporarily override the permanent value.
1 (CONTINUE): Continue with stopped motion.
2 (NEXTMOTION): abort current motion and execute the next motion command in the motion buffer.
3 (CLEARMOTION): Abort all motion commands in the motion buffer.
Syntax
<axis>.ProceedType = <expression>
? <axis>.ProceedType
Availability
All versions
Type
Long
Range
1 to 3
Default
3
Scope
Configuration, Task or Terminal
Examples
Axis1.ProceedType = Continue
?A1.ProceedType
Proceed XYTable ProceedType=Next