Difference between revisions of "MC-Basic:axis.DRIVESTATUS"
Line 143: | Line 143: | ||
{{!}}Drive Shutdown - Error in C1D | {{!}}Drive Shutdown - Error in C1D | ||
{{!}} | {{!}} | ||
− | {{!}} | + | {{!}} |
{{!}}- | {{!}}- | ||
{{!}}14 | {{!}}14 | ||
{{!}}Drive status | {{!}}Drive status | ||
{{!}}'''0 - ''' Disabled <br> '''1 - ''' Enabled <br> DS402: rtso AND so AND voltage_en AND oper_en | {{!}}'''0 - ''' Disabled <br> '''1 - ''' Enabled <br> DS402: rtso AND so AND voltage_en AND oper_en | ||
− | {{!}} 0 | + | {{!}} 0(RTS) and 1 (SO) and 2 (OE) |
{{!}}- | {{!}}- | ||
{{!}}15 | {{!}}15 | ||
{{!}}Drive high power | {{!}}Drive high power | ||
{{!}}'''0 - ''' High power off <br> '''1 - ''' High power on <br> DS402: rtso AND so AND voltage_en | {{!}}'''0 - ''' High power off <br> '''1 - ''' High power on <br> DS402: rtso AND so AND voltage_en | ||
− | {{! | + | {{!}} 0 AND 1 AND 2 AND 4 |
{{!}}- | {{!}}- | ||
{{!}}21 | {{!}}21 |
Revision as of 07:05, 25 July 2022
Language: | English • 中文(简体) |
---|
This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Lower 16 bits reflect drive status word, i.e. the StatusWord (object 0x6041/0).
You can find more information at the CDHD manual or at the stepIM manual
Bit - DS402 | axis.DRIVESTATUS | Description | Values |
0 | 0 | Ready to switch on | 0 - Doesn't ready to switch on 1 - Ready to switch on |
1 | 1 | Switched on | 0 - Doesn't switched on 1 - Switched on |
2 | 2 | Operation enabled | 0 - Disabled 1 - Enabled |
3 | 3 | Fault | 0 - No fault in the system 1 - Fault in the system |
4 | 4 | Voltage enabled | 0 - High voltage applied 1 - High voltage not applied |
7 | 7 | Warning | NOTE - warning isn't an error |
11 | 11 | Internal limit active | 0 - activated 1 - not activated |
12 | 12 | Status command value processing | 0 - Drive ignores the command values (e.g., during Halt drive, drive controlled functions, programmed delay times) 1 - Drive follows the command values |
29 | Data invalid | 0 - motion bus data is valid 1 - motion bus data is not valid - corrupted or missing | |
30 | Limit Switch in Drive (from version 0.4.20.4) | 0 - Negative Limit switch is not active 1 - Limit switch is active | |
31 | Limit Switch in Drive (from version 0.4.20.4) | 0 - Positive Limit switch is not active 1 - Limit switch is active |
AnyBus (legacy SERCOS)
Bit | Description | Values | equivalent DS402 |
0 | AHS | 0 or 1 - Service transport handshake of the drive | |
1 | Busy | 0 - Step finished, ready for new step 1 - Step in progress, new step not allowed |
|
2 | Error in service channel | ||
3 | Status command value processing | 0 - Drive ignores the command values (e.g., during Halt drive, drive controlled functions, programmed delay times) 1 - Drive follows the command values |
12 (mode specific) |
4 | Parameterization levels (PL1, PL2) | 0 - PL1 and PL2 not active. 1 - PL1 or PL2 active. |
|
5 | Procedure command change bit | ||
6 | Real-time status bit 1 | ||
7 | Real-time status bit 2 | not used | |
8, 9, 10 | Actual operation mode | 0 0 0 - Primary operation mode (defined by S-0-0032) 0 0 1 - Secondary operation mode 1 (defined by IDN 33) 0 1 0 - Secondary operation mode 2 (defined by IDN 34) 0 1 1 - Secondary operation mode 3 (defined by IDN 35) |
not used |
11 | Change bit for C3D | ||
12 | Change bit for C2D | 7(warning) | |
13 | Drive Shutdown - Error in C1D | ||
14 | Drive status | 0 - Disabled 1 - Enabled DS402: rtso AND so AND voltage_en AND oper_en |
0(RTS) and 1 (SO) and 2 (OE) |
15 | Drive high power | 0 - High power off 1 - High power on DS402: rtso AND so AND voltage_en |
0 AND 1 AND 2 AND 4 |
21 | Fault | 3 (FLT)
} Short form<axis>.DStat Syntax?<axis>.DriveStatus AvailabilityAll versions TypeLong ScopeConfiguration, Task or Terminal LimitationsRead only. Bits 0,1,2,4,5,6,7,8,9,10,11,12 are applicable only to SERCOS Examples?a1.dstat If (a1.dstat band 2^14) Then ‘Check whether the drive is enabled See Also
|