Difference between revisions of "MC-Basic:axis.BUSNUMBER"
m |
(the default busnumber value is updated to 4) |
||
Line 1: | Line 1: | ||
− | {{Languages|MC-Basic:axis.BUSNUMBER}} | + | {{Languages|MC-Basic:axis.BUSNUMBER}} |
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 16: | Line 16: | ||
|RANGE= | |RANGE= | ||
− | ( | + | (4) - Default value, after start up or "reset all"<br> |
0 - EtherCAT<br> | 0 - EtherCAT<br> | ||
1 - CANopen | 1 - CANopen |
Latest revision as of 14:06, 1 April 2020
Language: | English • 中文(简体) |
---|
This property sets the field bus to which the axis is connected
Syntax
?<axis>.BusNumber
Availability
Since Version 4.15.2
0 - EtherCAT
1 - CANopen
Type
Long
Range
(4) - Default value, after start up or "reset all"
0 - EtherCAT
1 - CANopen
Scope
Configuration, Task or Terminal.
Limitations
Till version 4.15.2 Read-only
Examples
?Axis1.BusNumber