Difference between revisions of "MC-Basic:pls.PLSOUTPUT"

From SoftMC-Wiki
Jump to: navigation, search
(Removed obsolete "hw assistance" added limition - PlsOuput can be assigned upon completion of can/ethercat setup.)
m
Line 32: Line 32:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
The output is set only when the PLS is disabled.<br>
+
Can be set only when PLS is disabled.<br>
  
Network I/O: Output must exist. This property can be assigned only upon succesful completion of fieldbus (CAN/EthetCAT) setup.
+
The system output must exist. This property can be assigned only after successful completion of fieldbus (CAN/EthetCAT) setup.<br>
 +
 
 +
PLS high accuracy (HWAssistance) is limited to System.DOut from 1 to 8.
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 14:04, 10 October 2018

This property sets or queries the output associated with a PLS.

Short form

<pls>.Pout

Syntax

<pls>.PlsOutput = <system output>

?<pls>.PlsOutput

Availability

All versions

Range

Digital outputs: System.DOut.1 to 20

Virtual outputs: System.VOut.1 to 32

Default

The output associated with the PLS is defined when the PLS is declared (use COMMON SHARED <name> AS PLS).

Scope

Configuration, Task or Terminal

Limitations

Can be set only when PLS is disabled.

The system output must exist. This property can be assigned only after successful completion of fieldbus (CAN/EthetCAT) setup.

PLS high accuracy (HWAssistance) is limited to System.DOut from 1 to 8.

Examples

PLS1.Pout = System.DOut.5

?PLS1.PlsOutput                                         ‘returns “System.DOut.5”

See Also