Difference between revisions of "MC-Basic:pls.PLSOUTPUT"
(Removed obsolete "hw assistance" added limition - PlsOuput can be assigned upon completion of can/ethercat setup.) |
m |
||
Line 32: | Line 32: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | + | Can be set only when PLS is disabled.<br> | |
− | + | The system output must exist. This property can be assigned only after successful completion of fieldbus (CAN/EthetCAT) setup.<br> | |
+ | |||
+ | PLS high accuracy (HWAssistance) is limited to System.DOut from 1 to 8. | ||
|EXAMPLE= | |EXAMPLE= |
Revision as of 14:04, 10 October 2018
This property sets or queries the output associated with a PLS.
Short form
<pls>.Pout
Syntax
<pls>.PlsOutput = <system output>
?<pls>.PlsOutput
Availability
All versions
Range
Digital outputs: System.DOut.1 to 20
Virtual outputs: System.VOut.1 to 32
Default
The output associated with the PLS is defined when the PLS is declared (use COMMON SHARED <name> AS PLS).
Scope
Configuration, Task or Terminal
Limitations
Can be set only when PLS is disabled.
The system output must exist. This property can be assigned only after successful completion of fieldbus (CAN/EthetCAT) setup.
PLS high accuracy (HWAssistance) is limited to System.DOut from 1 to 8.
Examples
PLS1.Pout = System.DOut.5
?PLS1.PlsOutput ‘returns “System.DOut.5”