DecStop present the stopping deceleration in case of stop command from type DecStopOnPath. An additional use is done in internal system stopping procedure as when kill-task is operated (and slave=0 is given when conveyer tracking is on). This value is used when stop interrupts the next cases? -single axis movement,? or group movement from type Move or Circle.

Short form

<axis>.DecStop

Syntax

<axis>.DecelerationStop = <value>

Type

Double

Read/Write

Range

0.01 to Max Double

Units

Acceleration user units

Default

1000

Scope

Terminal or task

Limitations

Modal Only.

Examples

A1.DecStop = 1000