This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Following are the most important bit descriptions. <br> | This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Following are the most important bit descriptions. <br> | ||
<br> | <br> | ||
− | {{{!}}class = "wikitable" style="text-align: | + | {{{!}}class = "wikitable" style="text-align: left" |
{{!}}'''Bit''' | {{!}}'''Bit''' | ||
{{!}}'''Description ''' | {{!}}'''Description ''' | ||
Line 34: | Line 34: | ||
==='''Legacy SERCOS - <small><small>SERCOS only</small></small>'''=== | ==='''Legacy SERCOS - <small><small>SERCOS only</small></small>'''=== | ||
− | {{{!}} class = "wikitable" style="text-align: | + | {{{!}} class = "wikitable" style="text-align: left" |
{{!}}'''Bit''' | {{!}}'''Bit''' | ||
{{!}}'''Description ''' | {{!}}'''Description ''' |
Revision as of 12:55, 24 September 2017
Language: | [[::MC-Basic:axis.DRIVESTATUS|English]] • [[::MC-Basic:axis.DRIVESTATUS/zh-hans|中文(简体)]] |
---|
This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Following are the most important bit descriptions.
Bit | Description | Values |
15 | CAN and EtherCAT Reflect drive status object 0x6041/0 if mapped to PDO |
|
22 | Limit Switch in Drive (from version 0.4.17.2) | 0 - Limit switch is not active 1 - Limit switch is active |
21 | Data invalid | 0 - motion bus data is valid 1 - motion bus data is not valid - corrupted or missing |
Legacy SERCOS - SERCOS only
Bit | Description | Values |
0 | AHS | 0 or 1 - Service transport handshake of the drive |
1 | Busy | 0 - Step finished, ready for new step 1 - Step in progress, new step not allowed |
2 | Error in service channel | |
3 | Status command value processing | 0 - Drive ignores the command values (e.g., during Halt drive, drive controlled functions, programmed delay times) 1 - Drive follows the command values |
4 | Parameterization levels (PL1, PL2) | 0 - PL1 and PL2 not active. 1 - PL1 or PL2 active. |
5 | Procedure command change bit | |
6 | Real-time status bit 1 | |
7 | Real-time status bit 2 | |
8, 9, 10 | Actual operation mode | 0 0 0 - Primary operation mode (defined by S-0-0032) 0 0 1 - Secondary operation mode 1 (defined by IDN 33) 0 1 0 - Secondary operation mode 2 (defined by IDN 34) 0 1 1 - Secondary operation mode 3 (defined by IDN 35) |
11 | Change bit for C3D | |
12 | Change bit for C2D | |
13 | Drive Shutdown - Error in C1D | |
14 | Drive status | 0 - disabled 1 - enabled |
15 | Drive high power | 0 - high power off 1 - high power on |
Short form
<axis>.DStat
Syntax
?<axis>.DriveStatus
Availability
All versions
Type
Long
Scope
Configuration, Task or Terminal
Limitations
Read only.
SERCOS: Valid only in SERCOS communication phase 4.
EtherCAT: Valid only in OP mode.
EtherCAT and CAN: Limit switch state is reflected in bit #22.
Bits 0,1,2,4,5,6,7,8,9,10,11,12 are applicable only to SERCOS
EtherCAT/CANopen:
Bit 13: reflects state of bit #4 of status word (object 0x6041 subindex 0) and only if that object is mapped to PDO.
Examples
?a1.dstat
If (a1.dstat band 2^14) Then ‘Check whether the drive is enabled