Difference between revisions of "MC-Basic:axis.TIMEOFSHORTMOTIONS"

From SoftMC-Wiki
Jump to: navigation, search
(AXY: new links)
 
Line 1: Line 1:
{{Languages}}
+
{{Languages|MC-Basic:axis.TIMEOFSHORTMOTIONS}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 50: Line 50:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[AXY:MC-Basic:axis.TIMEACCMIN|TACCCMIN]]
+
* [[MC-Basic:element.TIMEACCMIN|TACCCMIN]]
* [[AXY:MC-Basic:axis.TIMEDECMIN|TDECMIN]]
+
 
  
 
}}
 
}}

Latest revision as of 12:44, 13 September 2017

Language: English

Defines the lower threshold below which TACCMIN and TDECMIN no longer affect motion. If the actual values of acceleration (or deceleration) time is below this limit, the entire excitation-limiting algorithm (TACCMIN and TDECMIN) is switched off.

CAUTION.svgCAUTION
The value of TSHORT is compared to acceleration/deceleration time only, and not to the entire duration of movement. Therefore, long movements with a long cruise-velocity phase and short acceleration/deceleration times could trigger the switch-off of the excitation-limiting algorithm. For best results, use small values (1 to 4 ms).


NOTE-Info.svgNOTE
Setting one of TACCMIN, TDECMIN or TSHORT to 0, completely disables the entire timing feature (excitation-limiting algorithm)

Short form

<axis>.TSHORT

Syntax

<axis>.TSHORT=<numeric expression>

Availability

Since Version 4.4.x

Type

Long

Range

0 to maxlong

Units

milliseconds (ms)

Default

0 – Not active

Scope

Task, Terminal

Limitations

  • Modal/Nodal
  • Read/Write

Examples

A1.timeaccmin = 500

A1.timedecmin = 1000

A1.timeofshortmotions = 200

See Also