Difference between revisions of "MC-Basic:axis.TIMEOFSHORTMOTIONS"
Line 51: | Line 51: | ||
|SEE ALSO= | |SEE ALSO= | ||
* [[AXY:MC-Basic:axis.TIMEACCMIN|TACCCMIN]] | * [[AXY:MC-Basic:axis.TIMEACCMIN|TACCCMIN]] | ||
− | * [[MC-Basic:axis.TIMEDECMIN|TDECMIN]] | + | * [[AXY:MC-Basic:axis.TIMEDECMIN|TDECMIN]] |
}} | }} |
Revision as of 07:31, 14 August 2017
Language: | [[::MC-Basic:axis.TIMEOFSHORTMOTIONS|English]] |
---|
Defines the lower threshold below which TACCMIN and TDECMIN no longer affect motion. If the actual values of acceleration (or deceleration) time is below this limit, the entire excitation-limiting algorithm (TACCMIN and TDECMIN) is switched off.
CAUTION | |
The value of TSHORT is compared to acceleration/deceleration time only, and not to the entire duration of movement. Therefore, long movements with a long cruise-velocity phase and short acceleration/deceleration times could trigger the switch-off of the excitation-limiting algorithm. For best results, use small values (1 to 4 ms). |
NOTE | |
Setting one of TACCMIN, TDECMIN or TSHORT to 0, completely disables the entire timing feature (excitation-limiting algorithm) |
Short form
<axis>.TSHORT
Syntax
<axis>.TSHORT=<numeric expression>
Availability
Since Version 4.4.x
Type
Long
Range
0 to maxlong
Units
milliseconds (ms)
Default
0 – Not active
Scope
Task, Terminal
Limitations
- Modal/Nodal
- Read/Write
Examples
A1.timeaccmin = 500
A1.timedecmin = 1000
A1.timeofshortmotions = 200