Difference between revisions of "SimulatedAxes"
Line 5: | Line 5: | ||
Simulated axis returns the same number of counts in feedback ([[MC-Basic:axis.COUNTFEEDBACK|CFB]]) as was given by command ([[MC-Basic:axis.COUNTCOMMAND|CCMD]]). | Simulated axis returns the same number of counts in feedback ([[MC-Basic:axis.COUNTFEEDBACK|CFB]]) as was given by command ([[MC-Basic:axis.COUNTCOMMAND|CCMD]]). | ||
− | {{Note| Position error ([[MC-Basic:axis.POSITIONERROR|PE]]) of a simulated axis is not always zero. The non-zero value can be due to: | + | {{Note| Position error ([[AXY:MC-Basic:axis.POSITIONERROR|PE]]) of a simulated axis is not always zero. The non-zero value can be due to: |
* Integer to float conversion (especially with very small [[MC-Basic:axis.POSITIONFACTOR|PFAC]]) values. | * Integer to float conversion (especially with very small [[MC-Basic:axis.POSITIONFACTOR|PFAC]]) values. |
Revision as of 07:04, 14 August 2017
Simulated Axes
An axis can be declared simulated by setting <axis>.simulated to 1.
Simulated axis returns the same number of counts in feedback (CFB) as was given by command (CCMD).
NOTE | |
Position error (PE) of a simulated axis is not always zero. The non-zero value can be due to:
|
NOTE | |
Since firmware Version 4.7.2, propagation delay of a simulated axes is accessible through these two user functions:
import_c sercSetSimulDelay(byval as long , byval as long ) as long import_c sercGetSimulDelay(byval as long , as long ) as long |
See Also: