Difference between revisions of "MC-Basic:SYSTEM.PIPEMODE"
m |
|||
Line 1: | Line 1: | ||
+ | {{Languages}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= |
Revision as of 06:54, 2 May 2017
Language: | [[::MC-Basic:SYSTEM.PIPEMODE|English]] • [[::MC-Basic:SYSTEM.PIPEMODE/zh-hans|中文(简体)]] |
---|
This property defines motion pipe mode type. Pipe mode types:
0 – Pipe mode is inactive
1 – Position pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[8] contain position commands for the respective axes.
2 – Position & Velocity pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[8] contain position and velocity commands for the respective axes.
Sys.VIn contains drive’s operation mode information.
Sys.Vin variable.defines the Operation modes for each axis are set 0 or 1.
The valid operation modes values are :
0 – Position operation mode
1 – Velocity operation mode
Short form
Sys.PMode
Syntax
Sys.PMode = <expression>
? Sys.PMode
Availability
Since Version 3.6.20
Type
Long
Range
0 , 1 or 2
Default
0
Scope
Config, Task or Terminal
Limitations
- Engaging sys.pipemode (1 or 2) is not allowed during motion. To leave pipemode, all axes pipemode property must be off.
- Read only
Examples
Sys.PMode = 1
?Sys.PMode