Difference between revisions of "MC-Basic:axis.POSITIONEXTROLLOVERENABLE"

From SoftMC-Wiki
Jump to: navigation, search
m (Miborich moved page Axystems:MC-Basic:axis.POSITIONEXTROLLOVERENABLE to MC-Basic:axis.POSITIONEXTROLLOVERENABLE: Global renaming of Axystems: namespace into (Main):)
Line 1: Line 1:
 +
{{Languages}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=

Revision as of 06:55, 20 April 2017

Language: [[::MC-Basic:axis.POSITIONEXTROLLOVERENABLE|English]]  • [[::MC-Basic:axis.POSITIONEXTROLLOVERENABLE/zh-hans|中文(简体)‎]]

This property is used to enable or disable position rollover on PEXT. When position external rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.
0 (OFF) - Rollover is disabled
1 (ON) - Rollover is enabled

Syntax

<axis>.PositionExtRollOverEnable= <option>

?<axis>.PositionRollOverEnable

Availability

All versions

Type

Long

Range

0 (OFF)
1 (ON)

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • The position rollover setting may be changed only when the axis is disabled.
  • To set the value within a task, the axis must be attached to that task (using the ATTACH command).

Examples

A1.PositionExtRollover  = 1000

Set rollover value

A1.PositionExtRollOverEnable = On

Enable position rollover

See Also