This property is used to query the current index of the cam table.The current index of the table is the row in the CAM data currently being accessed.

Short form

<axis>.Cind

Syntax

?<axis>.CamIndex

Availability

All versions

Type

Long

Range

1 to MaxLong

Default

1

Scope

Configuration, Task or Terminal

Limitations

Read only

The axis must be in the CAM mode of operation.

Examples

?Axis1.CamIndex