This property is used to query the current index of the cam table.The current index of the table is the row in the CAM data currently being accessed.
Short form
<axis>.Cind
Syntax
?<axis>.CamIndex
Availability
All versions
Type
Long
Range
1 to MaxLong
Default
1
Scope
Configuration, Task or Terminal
Limitations
Read only
The axis must be in the CAM mode of operation.
Examples
?Axis1.CamIndex